Features
● Reads any process pressure variable
● Dual switch outputs n4-20 mA auxiliary output signal
● Includes 17-4 PH stainless steel remote mount transducer
● Two protected adjustable set points - independently configured as rising or falling
● 4 1 / 2 digit display
● 101 segment bar graph with setpoint indication - linear or differential
● Menu driven software configuration (no external programming device required)
● Unique display shows both analog and digital values simultaneously; shows setpoint position and condition
Benefits
● Remote mount strain gauge transducer prevents process fluid from entering panel
● 4-20 mA output allows signal to be carried through to other measuring/control equipment
● User configurable software allows gauge to be utilized for various applications
● Bargraph provides operator with vital information "at a glance"
● Retrofits into existing gauge cutouts
Operation
AMOT Model 8575B µGauge is an electronic panel meter suitable for use in hazardous environments. The 8575B displays any single process pressure variable in a digital and analog format. As well as the dual display, the µGauge has 2 user configurable discrete outputs, and an additional 4-20mA output for retransmission of the process pressure to other equipment. The 8575B is designed to retrofit into an existing gauge hole and comes complete with an approved transmitter (AMOT Model 8580). The µGauge is completely configurable from the front panel. The user has ability to set the following parameters: Setpoints, Calibration, Averaging, Output Modes, Bar Graph, Range, Decimal Point Position, Least Significant Digit, Hysteresis, and Sensor Fail Action.
Specifications
Area Classification:
Area: Class 1, Division 1 and 2
Group: A, B, C & D
Approvals: CSA
Power Requirements: Table A
Voltage: 18-36 Vdc
Transducer Power: 5 Vdc max
IS Barrier: Voc: 28 Vdc max
Rs: 300W min. 2 System per Barrier
Environment:
Operating Temp. -4° to 140°F (-20° to 60°C)
Storage Temp. -4° to 167°F (-20° to 75°C)
Humidity: 10-100% non-condensing
Sealing: NEMA 4 (IP65) from front
NEMA 12 (IP54) from rear
Input
Type: Strain gauge bridge
Resistance: 3kW nominal, 1kW minimum
Sensitivity: 10mV / V
Range: 0 - 50m Vdc
Linearity: ±0.25% of full scale deflection
Accuracy: 0.5% of full scale deflection on gauge 0.5% of full scale deflection on transducer
Temperature Drift: 0.005% / °C
Input Impedance: >200kW
Wirelength: 50 feet max (20 AWG)
Outputs
Discrete
Quantity: 2 Type:
Transistor Isolation: optical, 2500 Vac
Voltage: 20 Vdc, max Current: 20 mA, max
Analog
Quantity: 1 Type: 4-20 mA
Isolation: none
Display
Type: Custom Analog / Digital LCD
Digital display: 4 1/2 digit plus sign
Analog display: 101 segment bar graph
Mechanical
Material: Flame retardant ABC with RFI shielding
Panel Cutout: 1.77" x 3.62" (92 x 45 mm)
Wiring: 2-part Phoenix, type MC, 3.8 mm pitch
Features
Two independently configurable setpoints
Sensor failure detection
Configurable setpoints hysteresis, 0%, 2%, 5%, 10% of full scale
|