Products
 
 
 
 
 
Product Datasheets

8575 - µGauge

8575 - µGauge

Features

Reads any process pressure variable

Dual switch outputs n4-20 mA auxiliary output signal

Includes 17-4 PH stainless steel remote mount transducer

Two protected adjustable set points - independently configured as rising or falling

4 1 / 2 digit display

101 segment bar graph with setpoint indication - linear or differential

Menu driven software configuration (no external programming device required)

Unique display shows both analog and digital values simultaneously; shows setpoint position and condition

Benefits

Remote mount strain gauge transducer prevents process fluid from entering panel

4-20 mA output allows signal to be carried through to other measuring/control equipment

User configurable software allows gauge to be utilized for various applications

Bargraph provides operator with vital information "at a glance"

Retrofits into existing gauge cutouts

Operation

AMOT Model 8575B µGauge is an electronic panel meter suitable for use in hazardous environments. The 8575B displays any single process pressure variable in a digital and analog format. As well as the dual display, the µGauge has 2 user configurable discrete outputs, and an additional 4-20mA output for retransmission of the process pressure to other equipment. The 8575B is designed to retrofit into an existing gauge hole and comes complete with an approved transmitter (AMOT Model 8580). The µGauge is completely configurable from the front panel. The user has ability to set the following parameters: Setpoints, Calibration, Averaging, Output Modes, Bar Graph, Range, Decimal Point Position, Least Significant Digit, Hysteresis, and Sensor Fail Action.

Specifications

Area Classification:

Area: Class 1, Division 1 and 2
Group: A, B, C & D
Approvals: CSA

Power Requirements: Table A
Voltage: 18-36 Vdc
Transducer Power: 5 Vdc max
IS Barrier: Voc: 28 Vdc max
Rs: 300W min. 2 System per Barrier

Environment:
Operating Temp. -4° to 140°F (-20° to 60°C)
Storage Temp. -4° to 167°F (-20° to 75°C)
Humidity: 10-100% non-condensing
Sealing: NEMA 4 (IP65) from front
NEMA 12 (IP54) from rear

Input
Type: Strain gauge bridge
Resistance: 3kW nominal, 1kW minimum
Sensitivity: 10mV / V
Range: 0 - 50m Vdc
Linearity: ±0.25% of full scale deflection
Accuracy: 0.5% of full scale deflection on gauge 0.5% of full scale deflection on transducer

Temperature Drift: 0.005% / °C
Input Impedance: >200kW
Wirelength: 50 feet max (20 AWG)

Outputs

Discrete
Quantity: 2 Type:
Transistor Isolation: optical, 2500 Vac
Voltage: 20 Vdc, max Current: 20 mA, max

Analog
Quantity: 1 Type: 4-20 mA
Isolation: none

Display
Type: Custom Analog / Digital LCD
Digital display: 4 1/2 digit plus sign
Analog display: 101 segment bar graph

Mechanical
Material: Flame retardant ABC with RFI shielding
Panel Cutout: 1.77" x 3.62" (92 x 45 mm)
Wiring: 2-part Phoenix, type MC, 3.8 mm pitch

Features
Two independently configurable setpoints
Sensor failure detection
Configurable setpoints hysteresis, 0%, 2%, 5%, 10% of full scale

8575 - µGauge

Display

8575 - µGauge

back to product categories >


This and other information from AMOT provide product or system options for further investigation by users having technical expertise. Before you select or use any product or system, it is important that you analyze all aspects of your application and review the information concerning the product in the current product catalog. The user, through its own analysis and testing, is responsible for making the final selection of the system and components and assuring that all performance, safety and warning requirements of the applications are met.

©1997-2005 AMOT